Videoswitch VT User Manual
Page 12

VT Series 2
User Manual
Page 12
Videoswitch
VT601c.doc
6.6 Set Multiple Alarm Dwell Time
To set the Multiple Alarm Dwell Time, press and hold the SET key and then also press and hold the
Monitor A Camera 2 key:
[SET] and [Camera 2]
Keep the keys held for the required duration. Every second the transmitter will bleep.
6.7 Set Alarm Relay Hold Time
To set the Alarm Relay Hold Time, press and hold the SET key and then also press and hold the Monitor
A Camera 3 key:
[SET] and [Camera 3]
Every second the transmitter will bleep. If the keys are released after just one beep, a relay hold time of
zero will be stored. Further beeps each represent 10 seconds of relay hold time.