AMETEK 1986 DN DeviceNet Resolver User Manual
Page 13
13
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
Parameter Instance #5 (Setpoint 1 on position)
Attribute ID Access Rule
Name
Data Type
Value
1
Get/Set
Parameter Value
USINT
Setpoint 1 on position
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x65 0x24 0x01 0x30 0x02”
4
Get
Descriptor
WORD
0x0000
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02
Parameter Instance #6 (Setpoint 1 off position)
Attribute ID Access Rule
Name
Data Type
Value
1
Get/Set
Parameter Value
USINT
Setpoint 1 off position
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x65 0x24 0x01 0x30 0x03”
4
Get
Descriptor
WORD
0x0000
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02
Parameter Instance #7 (Setpoint 2 on position)
Attribute ID Access Rule
Name
Data Type
Value
1
Get/Set
Parameter Value
USINT
Setpoint 2 on position
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x65 0x24 0x02 0x30 0x02”
4
Get
Descriptor
WORD
0x0000
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02
Parameter Instance #8 (Setpoint 2 off position)
Attribute ID Access Rule
Name
Data Type
Value
1
Get/Set
Parameter Value
USINT
Setpoint 2 off position
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x65 0x24 0x02 0x30 0x03”
4
Get
Descriptor
WORD
0x0000
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02