AMETEK 955D LDT User Manual
Page 9
9
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
Note:
Contact our Technical Support at 1-800-635-0289 for custom confi gurations.
955D
0120
E
VP
001
X
Number of Recirculations
001 (Standard) to 127
Interrogation Mode
I = Internal Interrogation
E = External Interrogation
955D BRIK with
Variable Pulse Output
Stroke Length
Insert stroke length to 0.1 inch. Enter as
a four-place number. Example A 12.0”
stroke enters as 0120. To convert a metric
stroke in millimeters, multiply millimeter
value by 0.03937 to arrive at inch value.
Output Mode
VP = Variable Pulse
Options
X = None
E = Wet environment.
Electronics sealed to IP68 Rating.
Variable Pulse
3.7 Catalog Numbering System
3.8 Specifi cations for 955D
General Specifi cations
Null Zone
3.00”
Dead Band
2.00”
Extrusion Assembly
Anodized Aluminum with gasket seals,
IP 67, IP 68 Optional
Connector
6 Pin, 12mm Euro Style Connector
Sensor Length
5” to 180”
Agency Approval
CE
Shock & Vibration
Random
Vibration
Shock
MIL-STD 810E, 10Grms random,
20Hz - 2K Hz
Tested to 40G
955D
0120
XX
X
955D BRIK with
Control Pulse or
Stop/Start Output
Stroke Length
Insert stroke length to 0.1 inch. Enter as
a four-place number. Example A 12.0”
stroke enters as 0120. To convert a metric
stroke in millimeters, multiply millimeter
value by 0.03937 to arrive at inch value.
Output Mode
CP = Control Pulse
RS = RS-422 Start/Stop Pulse
Options
X = None
E = Wet environment.
Electronics sealed to IP68 Rating.
Control Pulse or Stop/Start Pulse
Electrical Specifi cations
Input Voltage
Unipolar 13.5 to 30 VDC
Current Draw
2.5 watts maximum
Nonlinearity
+/- 0.05% of full stroke
Repeatability
+/- 0.006% of full stroke
Hysteresis
+/- 0.02% of full stroke
Operating Temperature -20° to 70° C
Storage Temperature
-40° to 85° C
Update Time
Controller Dependent
Specifi cations are subject to change
and are based on a typical 36” LDT.