0 storage and transport, 0 description, 1 scope of applications – ARI Armaturen TEMPTROL 774 EN User Manual
Page 3: 0 storage and transport 4.0 description
Rev. 0040702000 1011
Page 21
Operating and installation instructions
TEMPTROL
®
3.0 Storage and transport
- At -20°C to +65°C.
- The paint is a base coat to protect against corrosion during transportation and storage. Do
not damage paint protection.
4.0 Description
4.1 Scope of applications
Temperature regulators are used for „regulating the temperature of fluids, air or steam used
in heating and ventilation systems for industrial or residential applications, ocean going
vessels and also in cooling systems“ and complies to type of operating mode 2B acc. to
DIN EN 14597.
The information complies to the Pressure Equipment Directive 97/23/EC.
It is the responsibility of the machine planner to ensure compliance.
The special markings on the valve must be taken into account.
Refer to the catalogue sheet to see which materials are used in standard versions.
Please contact the supplier or the manufacturer if you have any questions.
ATTENTION !
- Protect against external force (like impact, vibration, etc.).
- Valve mountings such as actuator, capillary tube, bonnets, temperature sensors
must not be exposed to external forces, e.g. they are not designed for use as
climbing aids, or as connecting points for lifting gear.
- Suitable materials handling and lifting equipment should be used.
Refer to catalogue sheet for weights.
ATTENTION !
- Refer to the data sheet for applications, limits on use and possibilities.
- Certain media require or preclude the use of special materials.
- The valves are designed for standard operating conditions. If conditions exceed
these requirements, e.g. aggressive or abrasive media, the operator should
state the higher requirements when ordering.
- Valves made from grey cast iron are not authorised for use in systems subject
to TRD 110.