beautypg.com

0 care and maintenance, 1 cleaning, 2 tightening torques – ARI Armaturen Steam injector PN25 EN User Manual

Page 6: 0 troubleshooting, 0 troubleshooting table

background image

Page 6

Rev. 0040807017 1010

Operating and installation instructions

Steam injector

7.0 Care and maintenance

Maintanance and maintenance-intervals have to be defined by the operator according to
the requirements..

7.1 Cleaning

Injectors have no moving parts. They can be cleaned after dismantling from the pipe.

7.2 Tightening torques

(refer to Fig. 2 page 4 - Fig. 3 page 4)

8.0 Troubleshooting

In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.

If malfunctions cannot be eliminate with the help of the following table
9.0 Troubleshooting table”, the supplier or manufacturer should be consulted.

9.0 Troubleshooting table

ATTENTION !
- refer to item 10.0 and 11.0 prio
r to dismantling and repair work!
- refer to item 6.0 befo
re restarting the plant !

Pos.

Steam injector PN25

Torque (Nm)

Rp 1 - 1 1/2

8

Threaded pin

50

-

ATTENTION !
- It is essential that the safety regulations are observed when identifying faults.

ATTENTION !
- refer to item 10.0 and 11.0 prio
r to dismantling and repair work!
- refer to item 6.0 befo
re restarting the plant !

Fault

Possible cause

Corrective measures

Strong noise

Too low or too high steam pressure

Change steam pressure,
- use more or less steam injectors.

Too long heating-up time Heat output is too low

Rise steam pressure,
-install more steam injectors

Steam bubbles come out
of the water

Heat output is too high,
-immersion depth is too low

Use smaller nominal diameter,
-reduce steam pressure,
-install injector deeper