Operating and installation instructions

Condensate discharge temperature limiter

7.4 Tightening torques

(refer to Fig. 1 page 4 - Fig. 5 page 10)

8.0 Troubleshooting

In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.

If malfunctions cannot be eliminated with the help of the following table
9.0 troubleshooting table”, the supplier or manufacturer should be consulted.

Pos.

Condensate discharge
temperature limiter PN40

Torque (Nm)

6

Screw cap

100

24

Controller

80

8

Strainer plug

70

43

Plug 70

46

Blow down valve

70

46.1

Pressure screw

15

47

Thermoter adapter

50

47

Thermometer

50

-

ATTENTION !
It is essential that the safety regulations are observed when identifying faults.