beautypg.com

2 replacement of plug, stem and seat – ARI Armaturen WA 206R EN User Manual

Page 8

background image

Page 8

Rev. 0040319001 4709

Operating and installation instructions

3-way/str.thr. control valves - WA206/216/306/316

7.2 Replacement of plug, stem and seat

- Remove actuator. (Refer to operating instructions for actuator!)
Note:
If inlet B is fitted with a dummy flange (series WA206/216H and series WA316R), r
efer to item 7.3.
- First remove the connection parts of the pipe (Pos. 13, 14, 15)
- Remove retaining ring (pos. 4).
- By pressing down the stem (pos. 7) remove seat ring (pos. 2) with O-ring (pos. 3).
- Plug (pos. 5) and stem (pos. 7) can now be removed.
- Reassemble in the reverse order.

- To facilitate fitting the O-ring (pos. 3), lubricate lightly with grease (commercial EPDM-

compatible grease).

Note:
The plug (pos. 5) can only be replaced complete with stem (pos. 7). Only the seat (pos. 2)
for path B can be dilsmantled.

ATTENION !
Refer to item 10.0 and 11.0 before dismantling the valve.

ATTENION !
the O-ring (pos. 3) must be renewed during reassembly.

Fig. 8: WA306H, WA316H

Fig. 9: WA306R

Fig. 10: Plug

with soft seal