beautypg.com

0 troubleshooting, 0 troubleshooting table, 0 troubleshooting 9.0 troubleshooting table – ARI Armaturen WA 206R EN User Manual

Page 12

background image

Page 12

Rev. 0040319001 4709

Operating and installation instructions

3-way/str.thr. control valves - WA206/216/306/316

8.0 Troubleshooting

In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.

If malfunctions cannot be eliminate with the help of the following table
9.0 troubleshooting table”, the supplier or manufacturer should be consulted.

9.0 Troubleshooting Table

-

ATTENTION !
It is essential that the safety regulations are observed when identifying faults.

ATTENTION !
- read item 10.0 and 11.0 prior
to dismantling and repair work!
- read item 6.0 bef
ore restarting the plant !

Fault

Possible cause

Corrective measures

No flow

Valve closed

Open valve (using actuator)

Flange covers not removed

Remove flange covers

Little flow

Valve not sufficiently open

Open valve (using actuator)

Dirt sieve clogged

Clean / replace sieve

Piping system clogged

Check piping system

Kvs value of valve unsuitable

Fit valve with higher Kvs value

Valve stem moves in jerks. Valve plug slightly seized owing to solid

dirt particles

Clean internals, smooth rough spots

Valve stem or plug cannot
be moved.

Seatring and plug clogged with dirt

Clean seatring and plug with suitable
solvent

Valve plug seized in seatring or guide
owing to deposits or dirt in medium

Replace plug and seatring

With straight trough version, the O-ring
in the seat ring groove was not
removed

Remove O-ring; refer to item 7.3.3

Valve stem leaking.

Stem seal leaking

Replace stem seal;
refer to item 7.1

Leakage too high when
valve is closed.

Sealing surfaces of plug eroded or
worn

Replace plug; refer to item 7.3.2.

Sealing edge of seatring damages or
worn

Replace seatring; refer to item 7.3.2

Seatring and/or plug dirty.

Clean internals of valve

Actuator not powerful enough

Install more powerful actuator,
Check service data

Valve stem „hammers“.

flow in the closing direction

increase actuator force

This manual is related to the following products: