Str. thr. control valves - STEVI

®

440 / 441, 445 / 446

9.0 Troubleshooting table

ATTENTION !
- read item 10.0 and 11.0 prior
to dismantling and repair work!
- read item 6.0 bef
ore restarting the plant !

Fault

Possible cause

Corrective measures

No flow

Valve closed.

Open valve (using actuator).

Flange covers not removed.

Remove flange covers.

Little flow

Valve not sufficiently open.

Open valve (using actuator).

Dirt sieve clogged.

Clean / replace sieve.

Piping system clogged.

Check piping system.

Kvs value of valve unsuitable.

Fit valve with higher Kvs value.

Valve stem moves in jerks.

Stuffing box sealing too tight
(for valves with graphite packings).

Slacken screw joint (pos. 25/20.17)
slightly. Valve must nor start leaking!

Valve plug slightly seized owing to
solid dirt particles.

Clean internals, smooth rough spots.

Valve stem or plug cannot be
moved.

Seating and plug clogged with dirt;
especially with V-port and perforated
plugs.

Clean seating and plug with suitable
solvent.

Valve plug seized in seating or guide
owing to deposits or dirt in medium.

Replace plug and seating; use parts
made from different material if neces-
sary.

Valve stem leaking.

PTFE V-ring unit damaged or worn.

Replace ring pack (pos. 12);
refer to item 7.1.1

Stuffing box gland too slack in valves
with stuffing box packings.

Tighten screw joint (pos. 25);
refer to item 7.1.2.

Bellows defective in valves with bellow
seal.

Replace bellows unit;
refer to item 7.1.3

Leakage too high when
valve is closed.

Sealing surfaces of plug eroded or
worn.

Replace plug;
refer to item 7.2.1.

Sealing edge of seating damages or
worn.

Replace seating
(only at Series 445/446); refer to item
7.2.3, fit strainer if necessary.

Piston sealing ring worn (pressure-
relieved valves).

Replace sealing ring;
refer to item 7.2.2

Seating and/or plug dirty.

Clean internals of valve;
fit dirt sieve if necessary.

Pneumatic actuator not completely
vented; spring force not fully effective.

Vent actuator air chamber completely.

Actuator not powerful enough.

Install more powerful actuator.
Check service data.