Leakage too high when
valve is closed.

Sealing surfaces of seat/plug eroded or
worn.

Change valve or, if necessary,
seat/plug.

Sealing edge of seating damages or
worn.

Change valve or, if necessary, seat/
plug, fit strainer if necessary.

Seat/plug leaking due to dirt.

Clean internals of valve, fit strainer
if necessary.
Change valve or, if necessary,
seat/plug.

Unsafe rise in downstream
pressure.

Safety valve not present in downstream

pressure system.

Fit safety valve.

Safety valve too small / wrong size.

Reset safety valve and replace

if necessary.

Fault

Possible cause

Corrective measures