Operating and installation instructions

STOBU

®

PN63-160

Valve with throttling plug +
position indicator + lock-
ing device cannot be
opened.

Locking device has been tightened.

Release locking device.

Rattling / banging
of the plug design with
„loose plug“

Nominal diameter of the valve in com-
pliance to the flow rate is to big

Choose smaller nominal diameter
Use a plug damper execution: see
medium

- high flow turbulences;
- the valve with loose plug is mounted

directly by a centrifuged pump;

- behind pressure reduction stations;
- behind pipe elbows;
- in compact plants;
- expansion joints are missing;
- the pump is not mounted on a

damper;

- there is no flow stabilizing pipe length;
- there is no start-up bypass line

Alter the system
Use a plug damper execution: see
medium

Flange broken between
valve and piping.

Bolts tightened unevenly.
Mating flanges not properly aligned.

Re-align piping and fit new valve!

Fault

Possible cause

Corrective measures