HighPoint RocketRAID 1720 User Manual
Page 31
RocketRAID 1720 Driver and Software Installation
4 -
3.
Select the desired RAID level from the drop-down list.
4.
Enter a name for the array using the keyboard (this is optional), and click the Next
button.
5.
If you are creating a redundant array (RAID 1), select an initialization option. If
you are creating a RAID 0 or JBOD (volume), skip to step 6:
For RAID1 arrays, the default initialization method is “No initialization”.
6.
Select which disks are to be used to create the array. Highlight the desired disk
from the left-side of the interface (available disks), then click on the
button
to move the disk to the right side of the interface (selected disks). Disks must be
selected one a time.
If you wish to remove a selected disk, highlight it from the selected disk section,
and use the
button to move it to the available disk section.
Note: The selection sequence is important - the order in which the disks are
selected will determine the disk sequence of the array.
7.
Select the capacity - the RocketRAID 1720 can create arrays between partitions
on various disks. It is not limited to physical hard disk drives. As a result of this
feature, you have the option of assigning a physical disk to multiple RAID
arrays.
9