Command set – Vaisala WS425FG User Manual
Page 41

Chapter 4 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 39
All user configuration parameters are stored in the non-volatile
memory.
Command Set
There are 18 interrogation requests that the host system and/or operator
can send to the Ultrasonic Wind sensor. They are listed below. The
sensor response to each command consists of a fixed-length message.
In each of the command descriptions below, CR is an ASCII carriage
return control character and LF is an ASCII line feed control character.
The WA command is executed by the ASOS at an interval of between
one and thirty seconds. For the WA command, the sensor responds to
the ASOS interrogation poll within 250 milliseconds of receiving the
NOTE
The Ultrasonic Wind sensor only responds to upper case characters.
Table 3
Ultrasonic Wind Interrogation Requests
ASCII Request
Description
WB
Baud rate control
WFIRMWARE
Downloading firmware
WA
Average wind speed and direction message
WL
Heater function automatically controlled by sensor
WM
Heaters locked on
WN
Heaters locked off
WS
Verbose BIT results and status
WJ
Set speed and direction averaging time
WD
Report BIT status
WF
Send test data message
WR
Execute system reset
WCAL
Sensor self calibration
WH
Display sensor command Help menu
WT
Short response BIT results and status
WSST
Return static speed of sound and sonic
temperature
WSTK
Calibrate static speed of sound and sonic
temperature from ambient temperature
WCDV
Return sensor self calibration data
WATE
Return sensor measurement with reduced signal
amplitude