Locating the water heater, Clearances, Locating the water heater clearances – State SBL95 250NE A User Manual

Page 9: Caution, Fire or explosion hazard

background image

9

Do not install this water heater directly on a carpeted floor. A fire

hazard may result. Instead the water heater must be placed on a

metal or wood panel extending beyond the full width and depth

by at least 3 inches in any direction. If the heater is installed

in a carpeted alcove, the entire floor shall be covered by the

panel. Also, see the DrAINING requirements in MAINTeNANCe

Section.
The heater shall be located or protected so it is not subject to

physical damage by a moving vehicle.
Flammable items, pressurized containers or any other potential

fire hazardous articles must never be placed on or adjacent to

the heater. Open containers or flammable material should not be

stored or used in the same room with the heater.
The heater must not be located in an area where it will be subject

to freezing.
locate it near a floor drain. The heater should be located in an

area where leakage from heater or connections will not result in

damage to adjacent area or to lower floors of the structure.
When such locations cannot be avoided, a suitable drain pan

should be installed under heater. Such pans should be fabricated

with sides at least 2” deep, with length and width at least 2” greater

than diameter of heater and must be piped to an adequate drain.

Pan must not restrict combustion air flow.

ClearanCes

This water heater is approved for installation on combustible

flooring in an alcove with minimum clearance from combustion

construction as indicated in Figure 7 and Table 4.
In all installations the minimum combustible clearances from

vent piping shall be 6” (15.2 cm). Vent piping passing through a

combustible wall or ceiling must be a continuous run (no joints)

and retain 6” (15.2 cm) clearance unless an approved reducing

thimble is used.
A service clearance of at least 24” (61 cm) should be maintained

from serviceable parts.
taBle 4. minimum ClearanCes to ComBustiBle or

non-ComBustiBle ConstruCtion

Model

"A" right Side "b" left Side "C" back "D" Ceiling

Sbl81120Ne
Sbl81154Ne

Sbl95180Ne
Sbl95199Ne

Sbl95250Ne(A)

0"

0"

0"

12"

0 cm

0 cm

0 cm

30.5 cm

loCating the water heater

Property Damage Hazard

All water heaters eventually leak.

Do not install without adequate drainage.

CAUTION

When installing the heater, consideration must be given to

proper location. location selected should be as close to the

stack or chimney as practicable, with adequate air supply and as

centralized with the piping system as possible.

Fire or Explosion Hazard

Read instruction manual before

installing, using or servicing

water heater.

Avoid all ignition sources if you smell gas.

Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

Use only the gas shown on the water heater rating label.

Keep ignition sources away from faucets after extended

periods of non-use.

Maintain required clearances to combustibles.

Do not expose water heater controls to excessive gas

pressure.

There is a risk in using fuel burning appliances such as gas

water heaters in rooms, garages or other areas where gasoline,

other flammable liquids or engine driven equipment or vehicles

are stored, operated or repaired. Flammable vapors are heavy

and travel along the floor and may be ignited by the heater's

igniter or main burner flames causing fire or explosion. Some

local codes permit operation of gas appliances in such areas if

they are installed 18" or more above the floor. This may reduce

the risk if location in such an area cannot be avoided.