insulation Blanket

Do not obstruct water heater air intake

with insulating blanket.
Gas and carbon monoxide detectors

are available.
Install water heater in accordance with

the instruction manual.

Breathing carbon monoxide can cause brain damage or

death. Always read and understand instruction manual.

Breathing Hazard - Carbon Monoxide Gas

Insulation blankets are available to the general public for external

use on gas water heaters but are not necessary with these

products. The purpose of an insulation blanket is to reduce the

standby heat loss encountered with storage tank heaters. The

water heaters covered by this manual meet or exceed the energy

Policy Act standards with respect to insulation and standby heat

loss requirements, making an insulation blanket unnecessary.
Should you choose to apply an insulation blanket to this

heater, you should follow these instructions. See the Features

and Components section of this manual for identification of

components mentioned below. Failure to follow these instructions

can restrict the air flow required for proper combustion, potentially

resulting in fire, asphyxiation, serious personal injury or death.
• do not apply insulation to the front of the combustion

chamber flange plate to insure that the spark igniter, flame

sensor, and sightglass remain uncovered.

• do not cover the gas valve or the Temperature-Pressure

relief Valve.

• do not apply insulation within 5” (13 cm) of the blower, to

insure the safe operation of the blower assembly.

• do not apply insulation on the control box that encloses

the thermostat, ignition control, and variable frequency drive.

• do not cover the instruction manual. Keep it on the side of

the water heater or nearby for future reference.

• do obtain new warning and instruction labels from the

manufacturer for placement on the blanket directly over the

existing labels.

• do inspect the insulation blanket frequently to make certain

it does not sag, thereby obstructing combustion air flow.

hard water

Where hard water conditions exist, water softening or the

threshold type of water treatment is recommended. This will

protect the dishwashers, coffee urns, water heaters, water piping

and other equipment.
See the Maintenance Section in this manual for sediment and

lime scale removal procedures.

CirCulation pumps

A circulating pump is used when a system requires a circulating

loop or there is a storage tank used in conjunction with the water

heater. See Water Piping Diagrams in this manual for installation

location of circulating pumps.
See the Circulation Pump Wiring Diagrams (Figure 9.) in this

manual for electrical hookup information. Install in accordance

with the current edition of the National electrical Code, NFPA 70

or the Canadian electrical Code, CSA C22.1.
All-bronze or stainless steel circulating pumps are recommended

for use with commercial water heaters.

figure 7.

nsf leg kit

figure 8.

The NSF leg Kit (part number 9008214005) is needed only for

applications that must conform to NSF/ANSI Standard 5. The

installed height of the water heater will increase by 3" (7.6 cm) when

the leg kit is installed. Follow these steps to install the leg Kit. Use

caution to prevent damage to the unit when installing the leg Kit
1. lift, tilt or lay the unit on its side to access the bottom of the legs.
2. Position the extension under leg aligning the holes in the leg

extension with the holes in the leg. Assemble the bolt, bevel

washers, flat washers, and nut through the aligned holes in

the leg and leg extension as shown in Figure 8.

3. Once in place, tighten the nut and bolt assembly. Torque to 70

ft.lbs (9.67 kgf-m).

4. Insure that all four nut and bolt assemblies are torqued to the

specified value before placing the unit on the floor.