If you lack the necessary skills required to properly install
the electrical wiring to this solar storage tank water heater,

do not proceed but have a qualifi ed electrician perform the

installation.
When making the electrical connections, always make sure:

The electrical supply has the proper overload fuse or

breaker protection.

Wire sizes and connections comply with all applicable

codes.

Wiring is enclosed in approved conduit (if required by local

codes).

The solar storage tank water heater and electrical supply

are properly grounded.

Important: Do not use an extension cord to supply power

to this solar storage tank water heater. Be sure the power

supply is completely grounded before making connections.
Figures 4, 5, and 6 are provided as reference drawings

for the 120/240v 2-wire models only. Always reference the

wiring diagram located on the solar storage tank water

heater for the correct electrical connections and connect

the electrical supply to the solar storage tank water heater

in accordance with local utility requirements and codes.
When installing the electrical wiring to the solar storage

tank water heater:
1. Be sure tank is completely filled with water before

making any electrical connections. (See Figure 2)

Notice: Applying electrical power to elements that are not

submerged in water will destroy them. The manufacturer

will not warranty any elements damaged in this manner.

FIGURE 2
HEATING ELEMENT

2. Disconnect the electric power.

3. Loosen the screw holding the junction box cover to the

top of the solar storage tank water heater and set aside.

4. Connect the electrical supply to the solar storage tank

water heater in accordance with local utility requirements

and codes.

A standard 1/2 inch opening has been made in the junction

box for conduit connections.

5. Connect ground wire to green ground screw in the junction

box of the solar storage tank water heater. Reinstall the

junction box cover.

Sensor (Furnished by Installer)

Wires are provided from the sensor mounting stud to the

top of the solar storage tank. Attach the tank sensor to

these wires and mount the sensor to the solar storage tank

using the stud provided. The stud is located behind the

lower electrical access cover (See Figure 3). Connect the

two wires that exit through the top of the solar storage tank

enclosure to the solar control. These wires are designed to

be connected to an NEC CLASS II circuit only.

ELEMENT

PLUG

WIRES TO TOP OF

HEATER

SENSOR

MOUNTING

STUD

FIGURE 3

SENSOR MOUNTING STUD

FIGURE 4
120/240V 2-WIRE MODELS

JUNCTION BOX

COVER

GROUND

WIRE

CONDUIT

WHITE WIRE (120V MODELS)

RED WIRE (240V MODELS)

BLACK WIRE

GREEN

GROUND

SCREW

BLACK

WHITE

APPROVED CONNECTORS

FIGURE 5
WIRING DIAGRAM

120V MODELS ONLY

OVERLOAD

PROTECTION

NEUTRAL

HOT

CIRCUIT

BREAKER

TO 120/160V

POWER SUPPLY

ELECTRICAL

SERVICE GROUND

GROUND

SCREW

BLACK

RED

APPROVED CONNECTORS

FIGURE 6
WIRING DIAGRAM

208/240V MODELS ONLY

OVERLOAD

PROTECTION

TO 208/240V

@60Hz

1 PHASE

POWER SUPPLY

ELECTRICAL

SERVICE GROUND

L1

L2

CIRCUIT

BREAKER

GROUND

SCREW