beautypg.com

Water temperature adjustment, Operating mode descriptions, Other controls – State EPX 80 DHPT User Manual

Page 14

background image

14

Adjusting the User Interface Module/Operational Modes

°F/°C

LOCK

HEAT PUMP

ELEMENT

EFFICIENCY

F

VACATION

ELECTRIC

HYBRID

EFFICIENCY

Power Button: On - Green

Standby - Red

Temperature

Down (Decrease)

Button

Temperature

Up (Increase)

Button

Operational Mode Buttons

Water

Temperature

Set Point

Water Heater

Mode/Status

Indicator

Water Heater

Efficiency Status

Icon

LCD Display Panel

Lock Button

Fahrenheit/Celsius

Temperature Display

Button

LCD Control

Panel Lock Icon

Heat Pump

Functioning

Icon

Element

Functioning

Icon

Figure 11 User Interface Module

Water Temperature Adjustment

The water temperature can be adjusted from 95°F to 150°F.

Use the Up and Down Buttons

on the front

panel to set the desired temperature.

IMPORTANT:

Before attempting to adjust the thermostat,

read the “Water Temperature Regulation” section. If the

instructions are not clear, contact a qualified person.

IMPORTANT:

Filling a spa or hot tub from this water heater

may result in extended recovery/re-heat time. Switching

(temporarily) to Hybrid Mode or Electric Mode will decrease

the recovery/re-heat time. Be sure to switch back to the

desired operational mode when finished.

Operating Mode Descriptions

The operating modes can be changed by touching the

desired mode icon on the User Interface Module (see

Figure 11.)

NOTE: All buttons on the User Interface are touch sensitive

and require only a light touch to actuate.

HYBRID

Hybrid Mode - This is the default, recommended

setting. Combining high energy efficiency with

reduced recovery time. This mode uses the

heat pump as the primary heating source.

The heating element will heat water if demand

exceeds a predetermined level so that the

set point temperature can be recovered more

quickly.

EFFICIENCY

Efficiency Mode - Is the most energy efficient

mode. This mode uses the heat pump to heat

water in the tank. The elements are not used

unless the ambient operating temperature

is below 45°F or above 109°F. If hot water

demands are not met in Efficiency Mode it may

be necessary to switch to Hybrid Mode.

ELECTRIC

Electric Mode - The water heater functions as

a conventional electric unit, relying totally on

the elements to heat the water in the tank. This

mode may be useful in winter to eliminate the

output of cold air from the unit.

VACATION

Vacation Mode - The controller adjusts the

water temperature to approximately 60°F. This

mode is recommended when the water heater

is not in use for a long period of time. This mode

minimizes energy consumption and prevents the

water heater from freezing during cold weather.

NOTE: To activate the Vacation Mode touch the

vacation button. To deactivate Vacation Mode

touch the vacation button.

IMPORTANT: The

anode protecting the tank requires power to the

unit to operate. Do not shut off power to the unit

for extended periods of time. If power must be

turned off for an extended period of time, drain

the tank completely.

Other Controls

Lock - Holding this button for more than 3

seconds switches the lock mode on or off. When

the User Interface Module is locked a symbol

and “Lock” text will be visible on the display (see

Figure 11).

°F/°C

°F/°C - The button switches the display to show

the set temperature in Fahrenheit or Celsius.

This manual is related to the following products: