Wixey WR365 Digital Angle Gauge User Manual
Page 3
3
Trouble Shooting
Unstable constantly scrolling numbers
A. Remove the battery, wait 30 seconds and replace it.
B. Install new batteries.
Flashing digits, dim, or no display
A. Install new batteries.
B. Clean batteries and battery contacts.
Frozen display
A. Remove the battery, wait 30 seconds and replace it.
Dead Level
TM
calibration
The internal Dead Level
TM
setting is permanently calibrated at the factory
and should never need re-set. You can override this setting and calibrate it
yourself by following these 5 steps:
1. Hold the ON/ZERO while replacing the battery cover.
2. Place the gauge on a flat surface. The number “1” will appear on the
display.
3. Press the ON/ZERO button taking care not to move the gauge. The
number “1” will begin flashing.
4. After a few seconds the number “1” will change to the number “2”
5. Rotate the gauge 180 degrees, then press the ON/HOLD button taking
care not to move the gauge. The number “2” will begin flashing and
when it stops the display will go back to normal and the gauge has
been calibrated.
FIG 6
FIG 7