Operation, Charge controller block, Charge controller configuration block – Outback Power Systems AXS Port SunSpec Modbus Interface Owners Manual User Manual
Page 12: Table 2 charge controller block, Table 3 charge controller configuration block
Operation
10
900-0138-01-00 Rev
B
Charge Controller Block:
This block is usable for most OutBack charge controllers with the exception of the OutBack MX60. It is
a status-only block and does not contain command or control fields.
Table 2 Charge Controller Block
Start End Size R/W Name
Type
Units
Scale
Factor Contents Description
0 0 1 R C_SunSpec_DID
uint16 N/A
N/A 64111
Uniquely identifies this as a SunSpec Basic Charge
Controller
1 1 1 R C_SunSpec_Length
uint16 Registers N/A 23
Length
of
block in 16-bit registers
2 2 1 R CC_port_number
uint16 N/A
N/A 0-10
Port number on OutBack network
3 3 1 R CCconfig_Voltage_SF
int16
N/A
N/A
-1
DC Voltage Scale Factor
4 4 1 R CCconfig_Current_SF
int16
N/A
N/A
0
DC Current Scale Factor
5 5 1 R CCconfig_Power_SF
int16
N/A
N/A
0
DC Power Scale Factor
6 6 1 R CCconfig_AH_SF
int16
N/A
N/A
0
DC Amp Hours Scale Factor
7 7 1 R CCconfig_KWH_SF
int16
N/A
N/A
-1
DC kWH Scale Factor
8 8 1 R CC_Batt_Voltage_SF
uint16 Volts
Voltage
_SF
Measured Battery
Voltage
9 9 1 R CC_Array_Voltage_SF
uint16 Volts
Voltage
_SF
Measured
DC Source Voltage
10 10 1 R CC_Batt_Current_SF uint16
Amps
Voltage
_SF
Measured Battery
Current
11 11 1 R CC_Array_Current_SF uint16
Amps
Current
_SF
Measured DC
Source
Current
12 12 1 R CC_Charger_State
uint16 Enumerated N/A
Descriptive
0 = Silent; 1 = Float; 2 = Bulk; 3 = Absorb; 4 = EQ
13 13 1 R CC_Watts
uint16 Watts
Power
_SF Measured
CC
Wattage
Output
14 14 1 R
CC_Todays_Min_Battery_
Volts
uint16 Volts
Voltage
_SF
Measured
Minimum Voltage for battery today
15 15 1 R
CC_Todays_Max_Battery_
Volts
uint16 Volts
Voltage
_SF
Measured
Maximum Voltage for battery today
16 16 1 R CC_VOC
uint16 Volts
Voltage
_SF
Measured
Last Open Circuit Voltage (array)
17 17 1 R CC_Todays_Peak_VOC
uint16
Volts
N/A
Measured
Highest VOC today
18 18 1 R CC_Todays_kWH
uint16 KWH
KWH
_SF
Measured
Daily accumulated kilowatt-hours output
19 19 1 R CC_Todays_AH
uint16 AH
AH_SF Measured
Daily accumulated amp-hours output
20 20 1 R CC_Lifetime_kWH_Hours uint16 KWH
N/A
Measured
Lifetime Total kilowatt hours
21 21 1 R CC_Lifetime_kAmp_Hours uint16
Amps
KWH_
SF
Measured
Lifetime Total kiloamp-hours
22 22 1 R CC_Lifetime_Max_Watts uint16 Watts
Power_
SF
Measured Lifetime
Maximum
Wattage
23 23 1 R
CC_Lifetime_Max_Battery_
Volts
uint16 Volts
Voltage
_SF
Measured
Lifetime Maximum Battery Voltage
24 24 1 R CC_Lifetime_Max_VOC uint16 Volts
Voltage
_SF
Measured
Lifetime Maximum VOC
Charge Controller Configuration Block:
This block always accompanies the Charge Controller Block. It is usable for most OutBack charge
controllers with the exception of the OutBack MX60. It contains command and control fields for the
charge controller, as well as vendor-specific status fields.
Table 3 Charge Controller Configuration Block
Start End Size R/W Name
Type
Units
Scale
Factor Contents
Description
0 0 1 R C_SunSpec_DID
uint16 N/A
N/A
64112
Vendor Extension for OutBack Charge Controllers
1 1 1 R C_SunSpec_Length
uint16 Registers N/A 64
Length
of
block in 16-bit registers
2 2 1 R CCconfig_port_number uint16 N/A
N/A
0-10
Port number on OutBack network
3 3 1 R CCconfig_Voltage_SF
int16 N/A
N/A
-1
DC Voltage Scale Factor
4 4 1 R CCconfig_Current_SF
int16 N/A
N/A
0
DC Current Scale Factor
5 5 1 R CCconfig_Hours_SF
int16 N/A
N/A
-1
Time in Hours Scale Factor
6 6 1 R CCconfig_Power_SF
int16 N/A
N/A
0
Power Scale Factor
7 7 1 R CCconfig_AH_SF
int16 N/A
N/A
0
Amp Hours Scale Factor
8 8 1 R CCconfig_KWH_SF
int16 N/A
N/A
-1
DC kWH Scale Factor
9 9 1 R CCconfig_Faults
uint16 Bitfield N/A Descriptive
CC Error Flags: High VOC, Over temp, Shorted
Battery Temp Sensor
10 10 1 R/W
CCconfig_Absorb_Volts uint16 Volts
Voltage
_SF
Programmable Absorb Voltage Target