Commands – Outback Power Systems MATE3 USB Card Owner’s Manual User Manual
Page 20

Commands
18
900-0137-01-00 Rev
A
Table 21
Command/Response Definitions
Command
Response
Set inverter Selling disabled
Set inverter Selling enabled
Returns current inverter sell mode [SELL:s]
s = state,
0=disabled,
1=enabled
Sets inverter selling battery voltage where nn.n is the selling voltage
Increments inverter selling battery voltage
Decrements inverter selling battery voltage
Returns the selling voltage [SELLV:nnn] when nn.n is the battery selling voltage
Set the inverter’s charger(s) off
Set the inverter’s charger(s) auto
Set the inverter’s charger(s) on
Returns current charger mode [CHG:m] for inverter
m = mode,
0=Off,
1=On,
2=Auto
Sets inverter’s AC charger limit amps, where nn = AC charger amp limit
Increments inverter’s charger limits amps
Decrements inverter’s charger limits amps
Returns inverter’s AC charger limit amps [CHGLM:nn]
Sets inverter’s AC1 input limit amps
Increments inverter’s AC1 input limit amps
inverter’s AC1 input limit amps
Returns inverter’s AC1 input limit amps [AC1INLM:nn]
Sets inverter’s AC2 input limit amps
Increments inverter’s AC2 input limit amps
inverter’s AC2 input limit amps
Returns inverter’s AC2 input limit amps [AC2INLM:nn]
Starts system wide bulk charge (all ports)
Stops system wide bulk charge, ie goto float (all ports)
Returns the current bulk charge state [BLK:s] (all ports)
s = state,
s=2 bulk charge stopped,
s=1 bulk charge enabled
Returns inverter’s internal temperatures, p = port 0-10, [TEMP:p,F,C,X]
where p = port 1-10, F=FET, C=CAP, X=Transformer temps in degrees C
If inverter is a Radian series, it returns [TEMP:p, 1st module F=FET, C=CAP, X=Transformer, 2nd
module F=FET, C=CAP, X=Transformer]
Example
Returns battery temp value in degrees C [BTEMP:nnn] nnn in degrees C, can be a negative value
Sets system wide absorb voltage nn.n = absorb voltage (all ports)
Returns current system wide absorb voltage [ABSORBV:nnn] (all ports)
Set system wide absorb time in tenths of hours (all ports) Returns system wide absorb time in tenth of hours [ABSORBT:ttt] (all ports) Sets system wide float voltage nn.n = float voltage (all ports) Returns current system wide float voltage [FLOATV:nnn] (all ports) inverter’s float time in tenths of hours (all ports) Returns inverter’s float time in tenth of hours [FLOATT:ttt] (all ports) Returns firmware revision of software for device connected to port p [FIRM:V1.V2.V3] Returns MATE3 firmware revision [FIRM3:V1.V2.V3]