beautypg.com

Fr1051 – Flaming River FR1052 Electro-Wizard User Manual

Page 4

background image

The Flaming River FR1051 Disconnect Switch is designed to discon-
nect a vehicle electrical system using a toggle switch(Not Included).
The disconnect switch should be located as close as possible to the
battery. The toggle switch can be located in any convenient location
for ease of operator use.

1. Positive battery cable is connected to terminal 30 (POS.BATT.)
2. Vehicle load is connected to terminal 30A (POS.TEL.)
3. From terminal 85 (NEG.BOB.), connect a wire to one side of the

toggle switch. (Any style of “maintained” switch is acceptable, 10
amp or greater).

4. Connect the other side of the toggle switch to chassis ground.

When the operator closes the toggle switch, the solenoid in the
disconnect switch is activated. The switch will remain closed (on) as
long as terminal 85 is grounded.

• Always use proper wiring techniques.
• Wire size should be determined using industry standards based

upon load requirements and length of cable needed.

• Activation solenoid has a max draw of 4.4 amps, 0.4 amps con-

tinuous.

• Main terminals are rated for 250 amps continuous, 2500 amps

peak.

• We always recommend the use of Battery Terminal Covers

FR1003TM.

FR1051

Positive disconnection, 12V

GROUNDED SOLENOID (power supply coil negative)

This manual is related to the following products: