IV. SPECIFICATIONS

Range

Resolution

Accuracy

Acceleration 0.5 ~ 199.9 m/s

2

0.1 m/s2

+/- (5% +2d) rdg,
160 Hz, 80 Hz.
@ 23 +/- 5ºC

Velocity 0.5 ~ 199.9 mm/s 0.1 mm/s

GROUP G: Large machines on heavy foundations.

Good 0 ~ 1.80 mm/s

Acceptable 1.81 ~ 4.50 mm/s

Still permissible 4.51 ~ 11.2 mm/s

Dangerous > 11.2 mm/s

GROUP T: Largest machines and turbo machines with
special foundations.

Good 0 ~ 2.80 mm/s

Acceptable 2.81 ~ 7.10 mm/s

Still permissible 7.11 ~ 18.0 mm/s

Dangerous > 18 mm/s

J. ISO 2954 Sensitivity Relative Table

Frequency Hz

Relative sensitivity

Normal Value

Minimum Value Maximum Value

10

1.0

0.8

1.1

20

1.0

0.9

1.1

40

1.0

0.9

1.1

80

1.0

1.0

1.0

160

1.0

0.9

1.1

500

1.0

0.9

1.1

1000

1.0

0.8

1.1