beautypg.com

American Standard Ellisse 2711.XXXW User Manual

Installation instructions, Series whirlpool 2711.xxxw, Ellisse™ 6' x 48

background image

INSTALLATION INSTRUCTIONS

752296-100 REV. H

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

ELLISSE™
6' X 48"

SERIES WHIRLPOOL

2711.XXXW

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K Y O U . . .

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.

To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*

List of Required Components (not included):
• Drain 1583.470* • Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 20 amp
GFI Outlet
• Cement, Plaster,
Grout

1829mm

(72)

927mm

(36-1/2)

OUTLINE OF CUTOUT
1791 X 1181
(70-1/2 X 46-1/2)

C/L OF
DRAIN

102mm
(4)

PUMP

PROVIDE ACCESS

TO PUMP FOR SERVICE
ON ALL INSTALLATIONS

ON/OFF SWITCH

305mm

(12)

1219mm

(48)

229mm x 356mm
(9 x 14) FLOOR
CUTOUT

LEVELING STRINGER

(NOT FOR SUPPORT)

RECOMMENDED

FITTING

LOCATION
64X279mm
2-1/2 X 11)

1-1/2 N.P.T.M. THREADS

51mm

(2)

105mm

(4-1/8)

C/L OF
OVERFLOW

495mm

(19-1/2)

546mm

(21-1/2)

ROUGH

FLOOR

INTEGRAL

FEET

SUPPORT

1-1/2 O.D.TAILPIECE

OPTIONAL

DECK FITTING

AREA

GRAB BAR

FITTING AREA

64mm

(2-1/2)

121mm
(4-3/4)

SAFE-T-

HEATER
REMOVABLE

BLANK

GENERAL SPECIFICATIONS FOR 2711 WHIRLPOOL

72 x 48 x 21-1/2 In. (1829 x 1219 x 546mm)

148 Lbs. (67 Kg.)

965 Lbs. (434 Kg.)

95 Gal. (360 L)
74 Gal. (280 L)

43 x 28 In. (1092 x 711mm)
68 x 38 In. (1727 x 965mm)

14-5/8 In. (371mm)

40 Lbs./Sq.Ft. (195 Kgs./Sq.m)

30.3
60.8

2.1 HP, 14.4 AMPS ,120V.
2.1 HP, 15.6 AMPS ,120V.

SYSTEM I PUMP
SYSTEM II PUMP

WHIRLPOOL ELECTRICAL SPECIFICATIONS

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.

CUBE (FT

3

)