ADTRAN T1 CSU ACE User Manual
T1 csu ace
Table of contents
Document Outline
- Part Number 1203022L1
- Document Number 61203022L1-1B
- August 2004
- 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.
- 1. This equipment complies with Part 68 of FCC rules. On the back of the equipment housing is a label showing the FCC registration number and ringer equivalence number (REN). If requested, provide this information to the telephone company.
- Table of Contents
- List of Figures
- List of Tables
- Chapter 1 General
- Chapter 2 Installation
- Monitor Jacks
- Break-and-Test Jacks
- Power
- Network LOS
- 1. Verify that the cable from the network demarcation is in NET modular jack on the bottom/end of the T1 CSU ACE.
- 2. If all connections seem intact, the far end CSU ACE can be looped back (using a BERT test set to send the LB code, or using MANUAL LB at the other end) to isolate the problem to the far end customer premises or the network.
- 3. If the problem persists after the LB has been activated, the problem appears to be within the network or the far end CSU ACE. In this case, notify the carrier.
- 4. If the problem disappears after loop-up, then the cause must be at the far end customer premises.
- Equipment LOS
- Power On - Self Check Failure
- EPROM Checksum Failure
- Line
- Data Rate
- Signal Format
- Output Amplitude
- Network Connector Type
- Customer Interface Connector Type
- PWR
- SYNC
- Net LOS
- NET MAN LB
- NET RMT LB
- EQ LOS
- EQ MAN LB
- EQ RMT LB
- Local Power
- Temperature
- Relative Humidity