INSTALLATION INSTRUCTIONS

791031-100 Rev. H

© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

AMERICAST BRAND
ENGINEERED MATERIAL

STRATFORD™

WHIRLPOOL/BATHING POOL

2470.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K Y O U . . .

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.

To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*

* see your American Standard Distributor

List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout

203mm

(8)

1676mm

(66)

813mm

(32)

PROVIDE ACCESS

TO PUMP FOR

SERVICING

ON ALL

INSTALLATIONS

235mm

(9-1/4)

406mm

(16)

OUTLINE OF 1638 X 775mm
(64-1/2 X 30-1/2) CUTOUT

19mm
(3/4)

C/L OF 1/2
SUPPLIES

AS REQUIRED

FINISHED
WALL

PUMP

ON/OFF

SWITCH

32mm
(1-1/4)

C/L OF DRAIN
OUTLET

229 X 305mm
(9 X 12) FLOOR CUTOUT

508mm

(20)

476mm

(18-3/4)

MIN.

32mm
(1-1/4)

1-1/2 N.P.T. THREADS

1-1/2 O.D. TAILPIECE

70mm

(2-3/4)

117mm (4-5/8)

SUPPORT
STRINGER

324mm

(12-3/4)

102mm
(4)

711mm

(28)

32mm (1-1/4) DIA. HOLE
1/2 N.P.T. SHOWER

44mm (1-3/4) DIA. HOLES
FOR CONTROL VALVES

32mm (1-1/4) DIA. HOLE FOR
1/2 N.P.T. SPOUT

203mm
(8)

1651-1982mm

(65-78)

OPTIONAL

1/2 SUPPLIES

AS REQ'D

C/L OF SHOWER

CURTAIN ROD

1930mm (76)

OPTIONAL

TO FLOOR

70mm

(2-3/4)

FINISHED
WALL

C/L OF
OVERFLOW

76mm

(3)

SAFE-T-HEATER

REMOVABLE BLANK

GENERAL SPECIFICATIONS FOR 2470 WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

1.6 HP, 9.7 AMPS,120V.

66 x 32 x 20 In. (1676 x 813 x 508mm)

201 Lbs. (90 Kg.)

701 Lbs. (315 Kg.)

60 Gal. (227 L)
40 Gal. (152 L)

42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)

14 In. (356mm)

55 Lbs./Sq.Ft. (223 Kgs./Sq.m)

13.9
33.7

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)