Clinton Electronics CE-M10S User Manual
Page 16

16
This function reduces the background noise in a low luminance environment.
1. When the SETUP menu screen is displayed, select ‘DNR’ by using the Up and Down buttons so
that the arrow indicates ‘DNR’.
2. Select a desired mode using the Left and Right buttons.
OFF: Deactivates DNR. Noise is not reduced.
ON : Activates DNR so that noise is reduced.
3. Set the DNR mode to ‘ON’ and press the SET button. Then you can adjust the noise reduction
level.
DNR3
Notes
You cannot set the DNR to ‘ON’ or ‘OFF’ when the AGC mode of the EXPOSURE menu is ‘OFF’.
•
When adjusting the noise reduction level in DNR mode, remember that the higher the level is set,
•
the greater the reduction in noise level, as will the brightness of the image.