beautypg.com

Warning, Installation preparation, Power supply locations – GE ZDP364NDPSS User Manual

Page 9

background image

POWER SUPPLY LOCATIONS

Gas Supply:

• The natural gas models are designed to operate

at 5” water column pressure. For proper

operation, the pressure of the natural gas

supplied to the regulator must be between 7” and

13” water column.

• The LP models are designed to operate at 10”

water column pressure. For proper operation,

the pressure of the LP gas supplied to

the regulator must be between 11”

and 13” water column.

• A 1/2” elbow is provided for connection

to the range gas inlet, located at the rear

and near the floor.

• Locate the pipe stub on the back wall or floor

as illustrated in “Dimensions and Clearances.”

Use 5-foot maximum length, 5/8” O.D. flexible

gas supply line (3-foot in Massachusetts).

• Install a manual shut-off valve in the gas line

(not provided), in an easily accessible location.

Make sure the homeowner knows where

and how to shut off the gas supply to the range.

9

If the electrical service provided does not meet

the above specifications, it is recommended that

a licensed electrician install an approved outlet.
• Locate the electric supply as illustrated

in “Dimensions and Clearances.”

WARNING

The range is equipped for use with an electrical

supply which uses a separate grounding conductor

(4 wire system).
If this range must be connected to an electrical

system which utilizes a single conductor for ground

and neutral (3 wire system), the grounding jumper

at the terminal block must be connected.

The grounding jumper is located to the right

of the terminal block.

See 3-wire power cord installation on the next page.

Electric Supply:

These ranges must be supplied with 208/240 volt,

60 Hz., and connected to an individual, properly

grounded branch circuit protected by a circuit

breaker or time delay fuse (50 amp for 48” ranges,

30 amp for 36” and 30” ranges). The receptacle

must be a NEMA 14-50R device to accept the

4-prong plug supplied with the range.

Installation Preparation

The access

plate is on the

back

of the range.

This manual is related to the following products: