Read these instructions completely and carefully.

‡

IMPORTANT –

Save these instructions for

local inspector’s use.

‡

IMPORTANT –

Observe all governing

codes and ordinances.

‡

Note to Installer –

Be sure to leave these

instructions with the Consumer.

‡

Note to Consumer –

Keep these instructions

for future reference.

‡ Skill level – Installation of this appliance requires

basic mechanical and electrical skills.

‡ Completion time – 1–3 hours
‡ 3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
‡ 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW

covered under the Warranty.

‡ 8VHRQO\ZLWKDSSURYHGFRUGNLW-;+&

DUCTWORK REQUIREMENTS

WARNING –

Before beginning the

installation, switch power off at service panel and lock

the service disconnecting means to prevent power

from being switched on accidentally. When the service

disconnecting means cannot be locked, securely fasten

a prominent warning device, such as a tag, to the

service panel.

FOR YOUR SAFETY:

Questions?

Call

800.GE.CARES (800.432.2737)

RU9LVLWRXU:HEVLWHDW

GEAppliances.com

Installation Range

Hood

Instructions

6

NOTE: Read the ductwork sections only if you do not have
H[LVWLQJGXFWZRUN,I\RXKDYHH[LVWLQJGXFWZRUNVNLSWRWKH

“Damage” section and proceed.

WARNING –

TO REDUCE THE RISK OF FIRE AND

723523(5/<(;+$867$,5%(685(72'8&7$,52876,'(³

DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR

CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
7KHYHQWLQJV\VWHPPXVWH[KDXVWWRWKHRXWVLGH
This hood can be vented vertically through upper cabinets

or horizontally through an outside wall. Ductwork is not

included.
When applicable, install any makeup (replacement) air

system in accordance with local building code requirements.

Visit GEAppliances.com for available makeup air solutions.

Exhaust connection:

7KHKRRGH[KDXVWKDVEHHQGHVLJQHGWRPDWHZLWK

standard 3

1

ø

4

µ[µUHFWDQJXODUGXFWLQJRUµGLDPHWHU

round ducting.

If a 6” round duct is required, a rectangular-to-round

transition adaptor must be used*. Do not use less than a 6”

diameter duct.

Maximum duct length:

For satisfactory air movement, the total duct length of a

3

1

ø

4

µ[µUHFWDQJXODUµGLDPHWHUURXQGGXFWshould not

H[FHHGHTXLYDOHQWIHHW
NOTE: It’s important that ducting be installed using the

most direct route and with as few elbows as possible.
7KLVHQVXUHVFOHDUYHQWLQJRIH[KDXVWDQGKHOSVSUHYHQW

blockages. Also, make sure dampers swing freely and

nothing is blocking the ducts.

Elbows, transitions, wall and roofcaps, etc.,

present additional resistance to airflow and are equivalent

to a section of straight duct longer than their actual

physical size. When calculating the total duct length, add

the equivalent lengths of all transitions and adaptors plus

the length of all straight duct sections. The charts on the

following pages show you how to calculate total equivalent
GXFWZRUNOHQJWKXVLQJWKHDSSUR[LPDWHIHHWRIHTXLYDOHQW

length of some typical ducts.

*

IMPORTANT: If a rectangular-to-round

transition adaptor is used, the bottom

corners of the damper will have to be cut

to fit, using the tin snips, in order to allow

free movement of the damper. Equivalent

lengths of duct pieces are based on actual

tests and reflect requirements for good

venting performance with any hood.