beautypg.com

Cadet™ 6' x 42" whirlpool and bathing pool, High gloss, Revised 2/08 – American Standard Cadet Whirlpool and Bathing Pool 2774.002 User Manual

Page 2

background image

H56

© 2008 AS America Inc.

464 mm

(18-1/4)

38mm

(1-1/2)

502mm

(19-3/4)

1-1/2 O.D.TAILPIECE

LEVELING
STRINGER
NOT FOR
SUPPORT

ROUGH

FLOOR

89mm

(3-1/2)

305mm

(12)

OPTIONAL TO

FINISHED FLOOR

USUALLY BETWEEN

1651 & 1981mm

(65 & 78)

C/L OF
OVERFLOW

102mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

C/L OF DRAIN

INTEGRAL

SUPPORT

FEET

SAFE-T-HEATER
REMOVABLE
BLANK

RECOMMENDED FITTING LOCATION

64 X 330mm (2-1/2 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING

LOCATION #1

1829 mm

(72)

1067mm

(42)

OUTLINE OF CUTOUT
1791mm x 1029mm
(70-1/2 X 40-1/2)

533mm

(21)

229mm

(9)

305 mm

(12)

57mm

(2-1/4)

(8) JETS

CUTOUT IN FLOOR
FOR DRAIN

PUMP

FINISHED

WALL

19 mm

(3/4)

229 mm

(9)

(2) AIR VALVES

PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS

RECOMMENDED FITTING LOCATION

76 X 330mm (3 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING
LOCATION

1829 mm

(72)

1067mm

(42)

OUTLINE OF CUTOUT
1784 mm x 1022mm
(70-1/4 X 40-1/4)

533mm

(21)

464 mm

(18-1/4)

38 mm

(1-1/2)

502 mm

(19-3/4)

1-1/2 O.D.TAILPIECE

INTEGRAL

FEET

LEVELING STRINGER

NOT FOR SUPPORT

ROUGH

FLOOR

229mm

(9)

305 mm

(12)

57mm

(2-1/4)

89mm

(3-1/2)

CUTOUT IN FLOOR
FOR DRAIN

FINISHED

WALL

305 mm

(12)

OPTIONAL TO

FINISHED FLOOR

USUALLY BETWEEN

1651 & 1981mm

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

72 x 42 x 19-3/4 In. (1829 x 1067 x 502mm)

137 Lbs. (62 Kg.)

821 Lbs. (372 Kg.)

82 Gal. (310 L.)
66 Gal. (256 L.)

50 x 27 In. (1270 mm x 686 mm)

65 x 33 In. (1651 x 838mm)

13 In. (330 mm)

42 Lbs./Sq. Ft. (203 Kgs/Sq. m.)

27.8

55.5

GENERAL SPECIFICATIONS FOR 2774 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIn. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

2.1 HP, 14.4 AMPS, 120V.

SYSTEM I PUMP

72 x 42 x 19-3/4 In.

(1829mm x 1067 mm x 502mm)

112 Lbs. (50 Kg.)

795 Lbs. (358 Kg.)

82 Gal. (311 l.)

50 x 27 In. (1270 mm x 686 mm)

66 x 33 In. (1676 x 838mm)

13 In. (330 mm)

41 Lbs./Sq. Ft. (197 Kgs/Sq. m.)

27.8
55.5

GENERAL SPECIFICATIONS FOR 2774 BATHING POOL

INSTALLED SIZE

WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF

BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

OPTIONAL 3 WALL TILING BEAD. KIT AND APRON NO. 9272.018 OR 9372.018 AVAILABLE AND MUST BE ORDERED SEPARATELY.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING

SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1

These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.

CADET™ 6' x 42"

WHIRLPOOL AND BATHING POOL

HIGH GLOSS

Revised 2/08

This manual is related to the following products: