Zoning User’s Guide
5-3
Detailed Zoning Examples
5
test180_Jr.admin> zoneCreate “ql_zone1”, “Private_ServerA; Private_StorageA”
test180_Jr:admin> zoneCreate “ql_zone1”, “Private_ServerA; Private_StorageA”
test180_Jr:admin> zoneCreate “ql_zone2”, “Private_ServerB; Private_StorageB”
test180_Jr:admin>zoneCreate “fabric_zone1”, “Fabric_ServerA; Fabric_StorageA”
test180_Jr:admin>zoneCreate “fabric_zone2”, “Fabric_ServerB; Fabric_StorageB”
test180_Jr:admin> cfgSave
Updating flash ...
test180_Jr:admin>cfgEnable “cfg1”
Setting switch to Fabric mode,
Committing configuration...done.
zone config “cfg1” is in effect
tesst180_Jr:admin>cfgShow
Defined configuration
cfg: cfg1 ql_zone1; ql_zone2; fabric_zone1; fabric_zone2
zone: fabric_zone1
Fabric_ServerA; Fabric_StorageA
zone: fabric_zone2
Fabric_ServerB; Fabric_StorageB
zone: ql_zone1
Private_ServerA; Private_StorageA
zone: ql_zone2
Private ServerB; Private StorageB
alias: Fabric_ServerA
50:06:0b:00:00:06:9a:d6
alias: Fabric_ServerB
50:06:0b:00:00:06:ad:10
alias: Fabric_StorageA
50:06:04:82:bc:01:0a:1b
alias: Fabric_StorageB
50:06:04:82:bc:01:9a:1c
alias: Private_ServerA