beautypg.com

HP D2000 Disk Enclosures User Manual

Page 46

background image

Large Form Factor D2600 disk enclosures — maximum capacity
configuration

This example illustrates cabling for a single-domain configuration. In this configuration, note the
following:

P1 on the disk enclosure I/O module is treated as the SAS “in” port.

P2 on the disk enclosure I/O module is treated as the SAS “out” port.

In single-domain configurations, one cable path is created between the host, the primary disk en-
closure, and additional cascaded disk enclosures. (Shown)

In dual-domain configurations, two cable paths are created between the host, the primary disk
enclosure, and additional cascaded disk enclosures.

1.

Host (server or controller
enclosure)

2.

Primary disk enclosure

3.

Additional cascaded disk
enclosures

Cabling examples

46