Cache LUN XP user guide for the XP10000/XP12000

15

NOTE:

If a RAID-5 or RAID-6 volume area is changed from priority mode to bind mode and no cache is

added, only 33 percent of the user data fits into the area previously assigned for priority mode. The

remaining 67 percent is used to save read/write data. If a RAID-1 volume area is changed from priority

mode to bind mode and no cache is added, only 50 percent of the user data fits in the area previously

assigned for priority mode. The remaining 50 percent is used to save read/write data. Changing the

mode without cache extension requires Cache LUN XP reconfiguration.

Mainframe systems

To calculate the cache size for mainframe systems:

1.

Calculate the converted values of the starting and ending addresses.
For specified LDEVs:

Setting value of ending address (CC) = (↓( (LDEV size Ч 15) - 1) ч 15↓)

Round down the calculated value between the two down arrows (↓) after the decimal point
Setting value of ending address (CC) is the value that is input to the operations box in the Cache

LUN pane)

Setting value of ending address (HH) = ( (LDEV size × 15) - 1) Mod15

Remainder is the setting value of ending address (HH)
Setting value of ending address (HH) is the value entered in the operations box on the Cache

LUN pane

Converted value of starting address = 0
Converted value of ending address = Setting value of ending address (CC) × 15 + Setting value of

ending address (HH)

Setting value of ending address (CC) and Setting value of ending address (HH) are the values

entered in the operations box on the Cache LUN pane

For specified volumes:

Converted value of starting address = Setting value of starting address (CC) × 15 + Setting value of

starting address (HH)

Setting value of ending address (CC) and Setting value of ending address (HH) are the values

entered in the operations box on the Cache LUN pane

Converted value of ending address = Setting value of ending address (CC) × 15 + Setting value of

ending address (HH)

Setting value of ending address (CC) and Setting value of ending address (HH) are the values

entered in the operations box on the Cache LUN pane

2.

Calculate the number of addresses between the starting and ending addresses calculated in

step 1

.

Number of addresses = Converted value of ending address - Converted value of starting

address +1

Calculate the number of addresses of cache used by the user data

3.

Calculate the required cache size according to the operation modes, or RAID levels, to use Cache

LUN XP.
a. Bind mode

RAID-1:
Required cache size = (Number of addresses Ч ( (128 Ч (512 + 16) ) Ч 2) ч 1,024

Units are KB

RAID types other than RAID-1:
Required cache size = (Number of addresses Ч (128 Ч (512 + 16) ) Ч 3) ч 1,024

Units are KB