Configuration, Versatile i/o enclosure, Table e-1 – HP Integrity NonStop H-Series User Manual
Page 57

M8201R Fibre Channel to SCSI Router Installation and User’s Guide — 529971-006
E- 1
E
Configuring the Fibre Channel to
SCSI Router for the Versatile I/O
Enclosure
This section includes:
Configuration
1. In SCF, issue this command:
SCF> ADD TAPE $tape, SENDTO STORAGE, LOCATION (group, module,
slot), SAC sac-id, PORTNAME 64-bit-portname, LUN lun-id
Example:
SCF> ADD TAPE $TAPE1, SENDTO STORAGE, LOCATION (100,2,1), SAC
1, PORTNAME 100000E00C00F000, LUN 1
The Fibre Channel to SCSI router can also be connected to a tape library.
shows the SCSI ID, router port number, and the LUN address for a tape
library and a tape drive.
Note. The LUN (logical unit number) in SCF should be 1 for the tape drive that is on bus 0 and
3 for the tape drive that is on bus 1.
Note. PORTNAME in SCF corresponds to the WWP name of the router. This name is located
on the back of the device.
Note. To understand the VIO enclosure group-module-slot numbering, see the Versatile I/O
Manual.
Table E-1. LUN Mapping Table for the Fibre Channel to SCSI Router
DEVICE
SCSI ID
Router PORT
LUN ADDRESS
Tape library
3
0
LUN 0
Tape drive
5
0
LUN 1
Tape library
3
1
LUN 2
Tape drive
5
1
LUN 3