Specifications, Environmental specifications, Server specifications – HP ProLiant BL685c Server-Blade User Manual
Page 78
Specifications 78
Specifications
In this section
Environmental specifications .................................................................................................................... 78
Server specifications............................................................................................................................... 78
Environmental specifications
Specification Value
Temperature range*
Operating 10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping -40
°
C to 60
°
C (-40
°
F to 140
°
F)
Storage
-20°C to 60°C (-4 to 140°C)
Maximum wet bulb temperature 30
°
C (86
°
F)
Relative humidity
(noncondensing)**
Operating 10%
to
90%
Shipping 10%
to
90%
Storage 10%
to
95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70
Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Specification Value
Height
36.60 cm (14.42 in)
Depth
50.90 cm (20.06 in)
Width
5.14 cm (2.03 in)
Weight (maximum)
10.34 kg (22.80 lb)