beautypg.com

Troubleshoot the tape configuration – HP Integrity NonStop J-Series User Manual

Page 71

background image

Configuring the ACL Tape Drive for the NonStop
BladeSystem Server

M8605A and M8606A ACL Tape Drive Installation and User’s Guide 546012-002

B- 3

Troubleshoot the Tape Configuration

Troubleshoot the Tape Configuration

Check that the processes on the CLIM are running and if they are not, start them.

If either of these conditions occur:

°

The SCF STATUS CLIM $ZZCIP.* command shows that the CLIM object is still
in the STARTING state after a few minutes, or

°

The SCF STATUS TAPE command shows that the tape drive is still in the
STARTING state after a few minutes

°

The OSM Service Connection indicates that the resource needs attention

Check for event messages in the Event Message Service (EMS) log. Use the OSM
Event Viewer to view the EMS log.

Refer to the Operator Messages Manual for cause, effect, and recovery
information for event messages.

This manual is related to the following products: