beautypg.com

HP ProLiant DL385 G5 Server User Manual

Page 15

background image

Component identification 15

Systems Insight Display

LED and color

Internal Health LED color

Status

Processor failure, socket X
(amber)

Red

One or more of the following conditions may
exist:

Processor in socket X has failed.

Processor X is not installed in the socket.

Processor X is unsupported.

ROM detects a failed processor during

POST.

Amber

Processor in socket X is in a pre-failure
condition.

PPM failure (amber)

Red

One or more of the following conditions may
exist:

PPM for processor 2 has failed.

PPM is not installed, but processor 2 is
installed.

I-PPM failure (amber)

Red

Embedded I-PPM for processor 1 has failed.

DIMM failure, slot X (amber) Red

One or more of the following conditions may

exist:

DIMM in slot X has failed.

Memory group is populated with different

DIMM types (all DIMMs are mismatched).

Amber

One or more of the following conditions may
exist:

DIMM in slot X is in a pre-failure condition.

Memory group is populated with different
DIMM types (at least one DIMM is good).

DIMM failure, all slots in one

bank (amber)

Red

One or more DIMMs has failed. Test each

bank of DIMMs by removing all other DIMMs.
Isolate the failed DIMM by replacing each

DIMM in a bank with a known working

DIMM.

DIMM failure, all slots in all
banks (amber)

Red

One or more DIMMs has failed. Test each
bank of DIMMs by removing all other DIMMs.

Isolate the failed DIMM by replacing each
DIMM in a bank with a known working

DIMM.

Overtemperature (amber)

Red

The server has detected a hardware critical
temperature level.

Fan (amber)

Amber

One fan has failed in redundant mode.

Red

One or more of the following conditions may
exist:

One fan has failed in non-redundant mode

The minimum fan requirements are not
being met. Two or more fans have failed

or are missing.