Troubleshooting

103

Node Interleaving disabled - Invalid memory configuration

Description: Each node must have the same memory configuration to enable
interleaving.

Action: Populate each node with the same memory configuration and enable
interleaving in RBSU.

There must be a first DIMM in pair if second DIMM in pair is
populated. Second DIMM in pair ignored.

Description: The first DIMM socket in the pair is not populated. The second
DIMM in the pair is not recognized or used.

Action: Populate the DIMM socket.

Unsupported DIMM(s) found in system. - DIMM(s) may not be
used

Description: Unsupported memory types found in system.

Action: Refer to the applicable server user guide memory requirements and
replace with supported DIMMs.

1610-Temperature Violation Detected. - Waiting 5 Minutes for
System to Cool

...Press Esc key to resume booting without waiting for the system to cool.

WARNING: Pressing Esc is NOT recommended as the system may shutdown unexpectedly.

Audible Beeps: None

Possible Cause: The ambient system temperature exceeded acceptable levels.

Action: Lower the room temperature.