Troubleshooting examples for intface, Example 1 – HP Integrity NonStop H-Series User Manual
Page 152

Troubleshooting
Library Media Manager Installation and User’s Guide— 529970-001
C -12
Troubleshooting Examples for INTFACE
the tape drives. Next, re-configure LMM with the tape drives in the correct order the
way the system saw them.
Possible Reason #2:
Another reason is that in a labeling process, OVERRIDE ON is not specified. It is
possible that the $ZSVR dismount message may contain another label than the bar-
code that LMM sees. If so, LMM will not dismount the tape due to a mismatch in the
labels. Click the OVERRIDE ON button in the Media Labeling tab on the LMM GUI
when trying to label your tapevolumes.
Troubleshooting Examples for INTFACE
Example 1
PROBLEM:
When I run the INTFACE program, control is never given back to my process...
SOLUTION:
Possible Reason #1:
Usually the problem here is that the INTFACE program is not running as a named
process. As of 08.28.01, the new INTFACE program must be named.
Possible Reason #2:
Another possible problem is that the SERVER INTFACE program could have been
placed on the client.
RUN INTFACE/NAME/
RUN INTFACE /NAME/ EXPORT 000000 $SYSTEM.TSILMMS
RUN INTFACE /NAME/ MOUNT 000000 $TAPE1 $SYSTEM.TSILMMS