Correcting enclosure ids, Next steps – HP 2000fc Modular Smart Array User Manual
Page 37

Chapter 2
Installing and Cabling Enclosures
37
Correcting Enclosure IDs
When installing a system with drive enclosures attached, the enclosure IDs might
not agree with the physical cabling order. This is because the controller might have
been previously attached to some of the same enclosures and it attempts to preserve
the previous enclosure IDs if possible. To correct this condition, make sure that both
controllers are up and perform a rescan using SMU or the CLI. This will reorder the
enclosures, but can take up to two minutes for the enclosure IDs to be corrected.
To perform a rescan using the CLI, type the following command:
To rescan using SMU, as an Advanced Manage user:
1. Select Manage > Utilities > Disk Drive Utilities > Rescan.
2. In the Rescan For Devices panel, click Rescan.
Next Steps
Now you are ready to connect the data and management hosts, as described in
Chapter 3.
rescan