beautypg.com

Requirements for the array, Channel adapter (chip), Data integrity check license key – HP StorageWorks XP Remote Web Console Software User Manual

Page 11: Requirements for the host server, Fibre channel interface, Raid manager, Operating system, Data integrity check operating, Environments and prerequisites

background image

Data Integrity Check XP for the XP12000/XP10000/SVS200 user guide

11

2

Data Integrity Check Operating Environments and

Prerequisites

Data Integrity Check requires the following:

A Command View XP array (see ”

Requirements for the array

” on page 11)

A Host server that supports an Oracle database and has RAID Manager installed (see

Requirements for the Host Server

” on page 11)

An Oracle-data validation service (see ”

Restrictions and Conventions

” on page 12

Requirements for the array

Data Integrity Check requires a properly configured array and a channel adapter with the correct
microcode.

Channel Adapter (CHIP)

Data Integrity Check supports the following CHIP types:

DKC-F510-32HS (16 ports/PCB)

DKC-F510-16HS (8 ports/PCB)

CAUTION:

If CHIPs are used that do not support Data Integrity Check are used with CHIPs that do

support Data Integrity Check, the validity of the data is not checked when the data processed with
the unsupported CHIPs. HP recommends you to update all the CHIPs so that they would support
Data Integrity Check.

Data Integrity Check License Key

You need to install the license key for Data Integrity Check on the array using Remote Web Console.
To install the license key, refer to the

HP StorageWorks XP Remote Web Console user guide.

Requirements for the Host Server

You will need the following items installed on the host server:

Fibre channel interface

A fibre channel connection is required between the host server and the array.

RAID Manager

RAID Manager version 01-16-03/05 or better is required.

Operating System

One of the following operating systems is required.

This manual is related to the following products: