test180_Jr:admin>cfgShow

Defined configuration

cfg: cfg1 ql_zone1; al_zone2; fabric_zone1;
fabric_zone2

zone: fabric_zone1

Fabric_ServerA; Fabric_StorageA

zone: fabric_zone2

Fabric_ServerB; Fabric_StorageB

zone:

ql_zone1
Private_ServerA; Private_StorageA

zone: ql_zone2

Private ServerB; Private StorageB

alias: Fabric_ServerA

50:06:0b:00:00:06:9a:d6

alias: Fabric_ServerB

50:06:0b:00:00:06:ad:10

alias: Fabric_StorageA

50:06:04:82:bc:01:0a:1b

alias: Fabric_StorageB

50:06:04:82:bc:01:9a:1c

alias: Private_ServerA

1,3

alias: Private_ServerB

1,4

alias: Private_StorageA

2,2

alias: Private_StorageB

2,1

Effective configuration:

cfg: cfg1

zone: fabric_zone1

50:06:0b:00:00:06:9a:d6
50:06:04:82:bc:01:9a:1b

zone: fabric_zone2

50:06:0b:00:00:06:ad:10
50:06:04:82:bc:01:9a:1c