Acceso a la CLI
IMPORTANTE:
Mantenga un registro de las unidades a medida que las crea. Los números de unidad se
utilizan en otros comandos de CLI. Además de registrar el número de unidad, las unidades incluidas, el
tipo de RAID y el tamaño, registre el orden en que se crearon.
Comando y respuesta de ejemplo para crear un LUN a partir de un grupo de unidades
CLI> add unit 0 data=”disk101-disk107 disk110” raid_level=6 stripe_size=64
First volume to be configured on these drives.
Logical Unit size = 69460 MB
RAID overhead = 0 MB
Total space occupied by new unit = 69460 MB
Free space left on this volume = 0 MB
Unit 0 is created successfully.
Comando y respuesta de ejemplo para crear varios LUN en un grupo de unidades
CLI> add unit 1 data=”disk111-disk114” raid_level=5 stripe_size=32
size=1000mb
First volume to be configured on these drives.
The logical unit size has been adjusted by 4MB for optimal performance.
Logical Unit size = 996 MB
RAID overhead = 498 MB
Total space occupied by new unit = 1494 MB
Free space left on this volume = 24533 MB
Unit 1 is created successfully.
CLI> add unit 2 data=”disk111-disk114” raid_level=5 stripe_size=32
size=2000mb
Logical Unit size = 2000 MB
RAID overhead = 1000 MB
Total space occupied by new unit = 3000 MB
Free space left on this volume = 21533 MB
Unit 2 is created successfully.
CLI> add unit 3 data=”disk111-disk114” raid_level=5 stripe_size=16
size=4000mb
Logical Unit size = 4000 MB
RAID overhead = 2000 MB
Total space occupied by new unit = 6000 MB
Free space left on this volume = 15533 MB
Unit 3 is created successfully.
Comando y respuesta de ejemplo para crear un LUN con un repuesto asignado
CLI> add unit 4 data=”disk211-disk212” raid_level=1 spare=”disk213”
First volume to be configured on these drives.
Logical Unit size = 69460 MB
RAID overhead = 69460 MB
Total space occupied by new unit = 138920 MB
Free space left on this volume = 0 MB
Unit 4 is created successfully.