beautypg.com

Raid 1 arrays, Raid 10 arrays, Raid 1 arrays raid 10 arrays – Adaptec ATA II 1220SA User Manual

Page 50

background image

Appendix A: Understanding RAID

50

RAID 1 Arrays

A RAID 1 array is built from two disk drives, where one disk drive is a mirror of the other (the
same data is stored on each disk drive). Compared to independent disk drives, RAID 1 arrays
provide improved performance, with twice the read rate and an equal write rate of single disks.
However, capacity is only 50 percent of independent disk drives.

If the RAID 1 array is built from different-sized disk drives, the free space, drive segment size is
the size of the smaller disk drive, as shown in the following figure.

RAID 10 Arrays

A RAID 10 array is built from two or more equal-sized RAID 1 arrays. Adaptec RAID
controllers support a maximum number of 48 disk drives in a RAID 10 array.

Data in a RAID 10 array is both striped and mirrored. Mirroring provides data protection, and
striping improves performance.

Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an
array with two 250 GB disk drives and two 400 GB disk drives can create two mirrored drive
segments of 250 GB, for a total of 500 GB for the array, as shown in the following figure.

Disk Drive 1

Disk Drive 2

250 GB

400 GB

Disk Drives in Logical Drive

Disk Drive 1

Disk Drive 2

RAID 1 Logical Drive = 250 GB

Not Used

Unused Space: 150 GB

1 – 250

1 – 250

Drive Segment Size (Smaller Disk Drive)

Disk Drive 1

Disk Drive 2

Disk Drive 3

Disk Drive 4

250 GB

250 GB

400 GB

400 GB

Disk Drives in Logical Drive

Disk Drive 1

Disk Drive 2

Disk Drive 3

Disk Drive 4

RAID 10 Logical Drive = 500 GB

1

2

1

2

Not Used

Not Used

3

4

3

4

500

499

500

499

...

...

...

...

Unused Space: 150 GB

Unused Space: 150 GB

Drive Segment Size (Smallest Disk Drive)

This manual is related to the following products: