beautypg.com

Permanent connection – AEG Lavamat 74900 User Manual

Page 47

background image

Important
The wires in the mains lead are coloured in accordance with the following
code:
Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

If you fit your own plug, the colours of the wires in the mains lead of your
appliance may not correspond with the markings identifying the terminals in
your plug, proceed as follows:
Connect the green and yellow (earth) wire to the terminal in the plug which
is marked with the letter «E» or the earth symbol

or coloured green and

yellow.
Connect the blue (neutral) wire to the terminal in the plug which is marked
with the letter «N» or coloured black.
Connect the brown (live) wire to the terminal in the plug which is marked
with the letter «L» or coloured red.
The plug moulded on to the lead incorporates a fuse. For replacement, use a
13 Amp BS1362 fuse. Only ASTA or BSI approved fuses should be used.
The plug must not be used if the fuse cover/carrier is lost. The cover/carrier is
indicated by the coloured insert at the base of the plug.
A replacement cover/carrier must be obtained from your local AEG/ELEC-
TROLUX Service Centre.

Permanent connection

In the case of a permanent connection it is necessary that you install a
double pole switch between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the switch contacts and
of a type suitable for the required load in compliance with the current
electrical regulations.
The switch must not break the yellow and green earth cable at any
point.
This operation must be performed by a qualified electrician.
Important: The power supply cable must be easily accessible after
installing the machine.

47

Installation

132978470 UK.qxd 21/02/2007 14.33 Pagina 47