Installation
F232058
Water Connection
Connections should be supplied by a hot and a
cold water line of at least the sizes shown in
the Water Supply Line Sizing table.
Installation of additional machines will require
proportionately larger water lines. See table.
To connect water service to machine with
rubber hoses, use the following procedure:
1. Before installing hoses, flush the water
system for at least two minutes.
2. Check filters in the washer-extractor’s
inlet hoses for proper fit and cleanliness
before connecting.
3. Hang the hoses in a large loop; do not
allow them to kink.
If additional hose lengths are needed, use
flexible hoses with screen filters. Each hose
should have a screen filter installed to keep
rust and other foreign particles out of the water
inlet valves.
Pressure of 30 – 85 psi (2 – 5.7 bar) provides
best performance. Although the washer-
extractor will function properly at lower
pressures, increased fill times will occur.
Suitable air cushions should be installed in
supply lines to prevent “hammering.” If the
water pressure is above 60 psi, flexible copper
tubing should be used in place of rubber hoses.
Water Supply Information
35
50
85
Water inlet
connection size,
in. (mm)
3/4 (19)
3/4 (19)
1 (25)
Number of water
inlets (standard)
2
2
2
Recommended
pressure psi (bar)
30–85
(2–5.7)
30–85
(2–5.7)
30–85
(2–5.7)
Inlet flow capacity,
gal-min (l-min)
(80 psi)
12 (45)
12 (45)
25 (52)
Water Supply Line Sizing
Model
Number
of
Machines
Supply Line Size
in. (mm)
Main
Hot/Cold
35
1
1 (25)
3/4 (19)
2
1-1/2 (38)
1 (25)
3
2 (50)
1-1/4 (32)
4
2 (50)
1-1/2 (38)
50
1
1-1/4 (32)
1 (25)
2
2 (50)
1-1/4 (32)
3
2 (50)
1-1/2 (38)
4
2-1/2 (64)
2 (50)
85
1
1-1/2 (38)
1 (25)
2
2 (50)
1-1/2 (38)
3
2 (50)
2-1/2 (64)
4
2-1/2 (64)