beautypg.com

Installation, Water connection – Alliance Laundry Systems BF50PV User Manual

Page 27

background image

25

Installation

F232058

Water Connection

Connections should be supplied by a hot and a
cold water line of at least the sizes shown in
the Water Supply Line Sizing table.
Installation of additional machines will require
proportionately larger water lines. See table.

To connect water service to machine with
rubber hoses, use the following procedure:

1. Before installing hoses, flush the water

system for at least two minutes.

2. Check filters in the washer-extractor’s

inlet hoses for proper fit and cleanliness
before connecting.

3. Hang the hoses in a large loop; do not

allow them to kink.

If additional hose lengths are needed, use
flexible hoses with screen filters. Each hose
should have a screen filter installed to keep
rust and other foreign particles out of the water
inlet valves.

Pressure of 30 – 85 psi (2 – 5.7 bar) provides
best performance. Although the washer-
extractor will function properly at lower
pressures, increased fill times will occur.

Suitable air cushions should be installed in
supply lines to prevent “hammering.” If the
water pressure is above 60 psi, flexible copper
tubing should be used in place of rubber hoses.

Water Supply Information

35

50

85

Water inlet
connection size,
in. (mm)

3/4 (19)

3/4 (19)

1 (25)

Number of water
inlets (standard)

2

2

2

Recommended
pressure psi (bar)

30–85

(2–5.7)

30–85

(2–5.7)

30–85

(2–5.7)

Inlet flow capacity,
gal-min (l-min)
(80 psi)

12 (45)

12 (45)

25 (52)

Water Supply Line Sizing

Model

Number

of

Machines

Supply Line Size

in. (mm)

Main

Hot/Cold

35

1

1 (25)

3/4 (19)

2

1-1/2 (38)

1 (25)

3

2 (50)

1-1/4 (32)

4

2 (50)

1-1/2 (38)

50

1

1-1/4 (32)

1 (25)

2

2 (50)

1-1/4 (32)

3

2 (50)

1-1/2 (38)

4

2-1/2 (64)

2 (50)

85

1

1-1/2 (38)

1 (25)

2

2 (50)

1-1/2 (38)

3

2 (50)

2-1/2 (64)

4

2-1/2 (64)

2 (50)

This manual is related to the following products: