beautypg.com

Safety instructions for the installer – AEG 95300KA-MN User Manual

Page 27

background image

27

Safety Instructions for the Installer

A device must be included in the electrical installation that makes it possiĆ

ble to isolate the appliance from the mains supply with a minimum contact

separation of 3 mm.

Suitable isolation devices are e.g. cut-outs, fuses (remove screw type fuses

from the holder), earth leakage trips and circuit breakers.

In respect of fire protection, this appliance corresponds to type Y (EN 60

335-2-6). Only this type of appliance may be installed with a high cupboĆ

ard or wall on one side.

It is not permitted to fit drawers below the cooking surface.

Protection against electric shock must be provided by the installation.

The kitchen unit in which the appliance is fitted must satisfy the requireĆ

ments of DIN 68930 in respect of stability.

Built-in ovens and cooking surfaces are fitted with special connector syĆ

stems. They may only be combined with appliances with a matching system.

All cut surfaces are to be sealed with a suitable sealant for protection

against moisture.

On tiled work surfaces, the joints in the area where the hob sits on the surĆ

face must be completely filled with grout.

Ensure that the seal is correctly seated in the frame and that it is seated

against the work surface without leaving any gaps. Additional silicon seaĆ

lant must not be applied, this will make removal more difficult in the event

of the need for service.

Installation Instructions