Use Step 10 to install rigid drain pipe.
6. To adapt a rigid drain pipe to the HP03 or HP04 system, do not attach
barbed hose fitting to valve. Instead, plumb rigid tubing directly to the 1/2"
male NPT drain fitting.
7. Cut and glue drain pipe to a suitable drain making sure it is secure.
8. Place bypass valve in "bypass" position
Figure 3
9. Fully open the house main water shutoff valve.
10.
Slowly, turn “INLET” bypass valve back in the “service” position. Allow
water to flow into the unit.
11.
Push and hold “extra cycle” button to allow unit to go into backwash.
12.
Allow unit to run to drain for approx 5 minutes.
13.
Check plumbing work for leaks and fix immediately if any are found.
14.
Push “extra cycle” momentarily to allow unit to advance to “rapid rinse”.
1. Bypass
2. Service
Inlet
Outlet