Specifications, Setup – Water Inc HOUSEPURE HP04 User Manual
Page 5
Specifications
Feedwater
! Do not use this system on water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system. !
Minimum inlet pressure: 40 psig
Maximum outlet pressure: 125 psig
Power
Voltage: 120VAC
Frequency: 60Hz
Power consumption: 7 Watts Maximum
Installation
Minimum ambient temperature: 34 degrees F
Maximum ambient temperature: 122 degrees F
Setup
Unpacking and Inspection
Check the system components for damage or missing parts.
Where to Install the Filter
Consider the following points when determining where to install the water filter:
• Place the system as close as possible to a sewer drain. Runs of up to 12’
elevation above the control head is permissible.
• Do not install the filter where it would block access to the water heater, or
access to the main water shutoff, water meter, or electrical panels.
• A 120V electrical outlet is needed to plug in the transformer. If the outlet is
remote (up to 100 feet), use 18 gauge wire to connect.
• Always connect the system to the main water supply pipe before the water
heater.
• Install the system where it will not be subject to temperatures outside of the
limits stated in the Specification section or to direct sunlight.