Troubleshooting
1. Filter Fails To
Backwash.
A. Electrical
service
to
unit has been
interrupted.
A. Assure
permanent
electrical service (check
fuse, plug, pull chain or
switch).
B. Timer
programming
bad (improper
programming).
B. Check programming and
reset as needed.
2. System Delivers
un-filtered Water.
A. By-pass valve is
open.
A. Close
by-pass
valve.
H. Improper
programming.
H. Reprogram the control to
the proper regeneration
type and frequency.
L. Unit is plumbed
backwards.
L. Check that the unit is
plumbed correctly.
N. Water pressure is too
low.
N. Line pressure must be at
least 20psi.
4. Loss of Water
Pressure.
A. Sediment buildup in
Media-Guard in
water filter.
A. Backwash more often.
Change Media-guard
B. Sediment buildup in
carbon in water filter.
B. Change
carbon
bed.