Troubleshooting guide – Water Inc BG 1000 User Manual
Page 7
1. Install batteries (included): Remove the battery compartment cover located on the
top of the unit and install two (2) “AAA” batteries. Replace battery compartment
cover. The LCD panel should now show “1,000 gal”.
2. Install fittings: The DigiFlow 8800T connection is 3/8” MNPT female. Fittings to
use are 3/8” MNPT male connection which is connected to the supply and feed
tubes. Install both fittings to a distance of 1/8” (0.32 cm) from flow monitor
housing (see figure 2 to the right).
3. Operation: The DigiFlow 8800T turns on and shows remaining capacity on the
screen when there is water flowing through it. The display on the LCD
screen turns off in 10 seconds if there is no water flowing. To check
the status of the remaining capacity of the installed cartridge, press the
“CHECK/RESET” button.
4. End of Cartridge Life Alarm: When the remaining capacity of the installed
cartridge reaches 0 gallons as indicated on the LCD screen, the PID will
sound a short “beep-beep” alarm and the “0” digit on the LCD screen
blinks, signaling time to replace the cartridge.
5. Reset PID: After the cartridge has been replaced, press the “CHECK/
RESET” button for four (4) seconds. A long “beep” sound can be heard
and the remaining capacity on the LCD screen is reset to 1,000 gallons.
6. Low Battery Power Alert: When the battery power is low and there is water flowing through the PID, a “beep-beep”
sound can be heard and the empty battery symbol on the LCD screen will blink to notify the user to change the
batteries. The PID will hold memory of total water flow recording while changing batteries.
OPERATION INSTRUCTIONS FOR THE DIGIFLOW 8800T
PERFORMANCE INDICATOR DEVICE (PID) —
BG-12000 Only
:
TROUBLESHOOTING GUIDE
Water Leaks at Push-In Connections:
Push tubing in as far as it will go. If leaking continues, shut off water at the original valve and remove water line by
pushing in on the connector collet while pulling the tubing away. Inspect tubing for cracks and scratches. If tubing is
cracked or scratched, simply cut that portion away and reinsert tubing into push-in fitting.
Make sure tubing is cut squarely. If not, recut correctly.
If water leaks, please verify that the o-ring is properly seated in its groove.
Water Does Not Flow From The Drinking Water System Faucet:
Check to see if the main water line valve is open, allowing water to flow to the filter. Make sure the connections are not
reversed.
Water Appears Cloudy or Air Comes Out of the Drinking Water System Faucet:
Flush filter for a minimum of 4 gallons (approximately 5 minutes), to remove any carbon fines or trapped air in the filter
and water lines.
For any service related issue, contact Water, Inc. at 1-800-322-WATER (9283), extensions 115 or 132
— 7 —
Figure 1
1/8”
(0.32 cm)
1/8”
(0.32 cm)
Figure 2